• Contractingbusiness 1317 13634ac01png00000006568

    2006 High Efficiency Air Conditioning Guide

    March 1, 2006
    The curtains officially up on the new, 13 SEER+ units from the industrys leading manufacturers. For more information on any of these products, visit us

    The curtain’s officially up on the new, 13 SEER+ units from the industry’s leading manufacturers. For more information on any of these products, visit us online at www.contractingbusiness.com

    Company or Brand/Model Compressor Type Efficiency Refrigerant Used Sound Level Elect. Rating/ Breaker Size Dimensions (in.) and weight Special Features AIR EASE
    4SCU13LE
    Copeland Scroll13 SEERR-410A73-77 dB15-60 ampsvariousSound blanket, louvered panels, wire fan guardAMANA
    ASX14
    High-efficiency Copeland Scroll14 SEERR-410An/a20-60 amps26H x 26W x 36D* wt. n/a *other sizes availableCopeland Comfort Alert ® diagnosticsAMERICAN STANDARD
    Allegiance 18
    Dual Duration ™18.9 SEERR-2272-78 dBn/a41H x 37W x 34D 404-416 lbs. (ship wt.)Two-row spine fin coilARCOAIRE
    DX1300
    Copeland Scroll13 SEERR-410A70-75 dB11.7-34.329 1 ⁄8 H x 31 3 ⁄16 W x 32 5 ⁄16 D* 160-265 lbs. *other sizes availableCompressor sound jacketARMSTRONG AIR 4SCU16LT
    Copeland Scroll16 SEERR-410A74-76 dB15-60 ampsvariousEmerson ® ComfortAlert diagnosticsBRYANT
    180A
    Two-stage scroll16 to 20 SEERPuron R-410A70 dB208-230-1 or 208-230-3 breakers40H x 35 1⁄2 W x 46D 300-360 lbs.7mm Microtube refrigeration technologyCARRIER
    Infinity 21 Series
    Two-stage scroll16 to 21 SEERPuron R-410A70 dBMCA: 13.9; Max. Fuse/Ckt. Bkr:2040H x 35W x 46D 300-320 lbs.State-of-the-art control interfaceCOLEMAN
    Echelon™ 5T
    Two-stage scroll15+SEERR-410A71-74dB20-50 amps33-39H x 37W x 31D 195-270 lbs.WhisperDrive systemCOMFORTMAKER
    SoftSound SX 2300
    Copeland Scroll13 to 14 SEERR-410A70-75 dB11.7-34.3 amps29 1 ⁄8 H x 31 3 ⁄16 W x 32 5 ⁄16 D* 160-265 lbs. *other sizes availableInnovative control box designCONCORD/ DUCANE
    2AC13
    Scroll and reciprocating13 SEERR-22Ducane: 74-79 dB Concord: n/a15-45 ampsvariousLouvered or non-louvered option; hinged access panelFEDDERS
    C24ABBD1V
    Copeland Scroll13 SEERR-22n/a15-50 amps23 1 ⁄2 H x 23 1 ⁄2 W x 27D* 118-241 lbs. *other sizes availableTotally enclosed PSC motorCompany or Brand/Model Compressor Type Efficiency Refrigerant Used Sound Level Elect. Rating/ Breaker Size Dimensions (in.) and weight Special Features FRIGIDAIRE
    FS4BF-024K
    Copeland Scroll16 SEERR-410An/a20 amps41H x 31W x 31D 253 lb.Variable speed motor reduces fan noiseGOODMAN
    GCS13 Series
    Copeland reciprocating13 SEERR-22 for 15-ft. of refrigerant lines76-80 dB15-50 amps26H x 26W x 29D* 173-258 lbs. *other sizes availableFactory installed liquid line filter dryerHEIL
    QuietComfort DX1300
    Copeland Scroll13 SEERR-410A70-75 dB11.7- 34.3 amps29 7 ⁄16 H x 31 3 ⁄16 W x 32 5 ⁄16 D* 160-265 lbs. *other sizes availableCompressor access panelLENNOX
    XC15 / XP15
    Copeland Scroll13-16.5 SEERR-410Amin. 64 dB17.4 amps39 1 ⁄2 H x 35 1 ⁄2 W x 37D 273 lbs.SmartHinge design for easy coil accessLUXAIRE
    Acclimate 5T
    Two-stage scroll15+SEERR-410A71-74 dB20-50 amps33-37H x 37W x 31D 195-285 lbs.Advanced fan design for smooth air flowMAYTAG
    PSA4BD-018K
    Copeland Scroll13 SEERR-410An/a20 amps36H x 23W x 23D 157 lbs.One-piece top provides max. airflowRHEEM
    Prestige Series
    Copeland Scroll18 SEERR-410A70.2 dBmin amps: 30/30 max amps: 40/4033H x 44W x 31D 236 lbs.Exclusive lower profile cabinetTAPPAN
    FS4BF-024K
    Copeland Scroll Ultra-Tech16 SEERR-410An/a20 amps41H x31W x 31D 253 lbs.One-piece top designed for maximum airflowTEMPSTAR
    SmartComfort TX 5300
    Copeland Scroll13 SEERR-410A70-75 dB11.7-34.3 amps29 7 ⁄16 H x 31 3 ⁄16 W x 32 5⁄16 D* 160-265 lbs. *other sizes availableHigh/low pressure switchesTRANE
    XL19I
    Dual Climatuff ®Up to 19.5 SEERR-410A72 dBV/PH/HZ = 200/230/1/6050H x 37W x 34D 392 lbs.DuraTuff basepan will not crack or warpWESTINGHOUSE
    FS4BF-024K
    Copeland Scroll Ultra-Tech16 SEERR-410An/a20 amps41H x 31W x 31D 253 lbs.Variable speed motor reduces fan noiseYORK
    [mc]2 MicroChannel
    1-2 tons: rotary 3 tons: recip.13 SEERR-2274-76 dB8.9-18.2 amps22H x 21W x 21D 85-140 lbs.Aluminum tube coil, for lightest 13 SEER to date
    TECHNICAL/PRODUCT CONSIDERATIONS BUSINESS/LOGISTICAL CONSIDERATIONS SALES / MARKETING CONSIDERATIONS

    Overall

    Get NATE certification

    Familiarize yourself with 13 SEER regulations to be able to answer any possible homeowner questions

    Prepare for increase in R-410A utilization:

    • 2010: all new installations must be R-410A
    • Get refrigerant charge correct per manufacturer instructions
    • If you’re not using R-410A yet, make sure your gauges can measure the higher pressures
    • Make sure recover units handle R-410A, older units will not

    For New Systems

    Review Manual J to ensure proper unit sizing and installation

    Get technical training on new products:

    • Understand your OEM’s system matches
    • Coils, TXVs, line sets, compressors, refrigerants
    • Motors
    • System set-up, troubleshooting, installation
    • IAQ and control products
    • Accessories, HRVs, filtering, controls

    For Existing Systems

    Know the impact of matching new outdoor units with old and new indoor units (warranty and performance)

    Bring TXVs to all job sites: many systems will require them

    Know how to properly clean a system

    • Filter dryers, oil removal, coil cleaning

    Overall

    Know the rules and products affected by the efficiency increase ( i.e., tonnage, single/three phase, residential/light commercial, etc.)

    Take advantage of distributor and manufacturer training programs

    Talk to your distributors about the support they will provide during and after the transition, and understand impact on deliveries, stock, etc.

    Increase stocking space for equipment: new equipment can be 30% larger

    Establish increased supply of TXVs, line sets

    Reorganize trucks to accommodate larger/heavier equipment

    Buy larger trucks if needed

    Look at crew size to accommodate larger equipment and to maximize labor

    Systems

    Establish phase-in/ phase-out of inventory:

    • Add new part numbers for new inventory

    Upgrade pricing software to include new components and manufacturing parts, equipment and labor

    Financial

    Do a margin analysis on systems and get salespeople on track with how to sell and improve margins

    Expand your line of credit: new equipment is more expensive

    Sit down with your builders and change house plans to accommodate new equipment and pricing

    Understand manufacturer warranty impact on business and customers

    Define warranty issues concerning mismatched systems

    Update bid packages to allow for new costs (equipment and labor)

    Before You Visit the Customer

    Plan to raise prices to provide profitability

    Learn new products and how to differentiate between them:

    • Understand indoor comfort story

    Compare new products to old to better explain the differences and benefits to homeowners

    Schedule and attend sales training:

    • Learn how to sell on comfort benefits along with efficiency

    Become proficient in Manual J load calculations so that you quote the proper size — do not oversize a 13 SEER unit

    Re-do pitch book to show new products and use manufacturer literature on new products

    Install a 13 SEER, variable-speed system and IAQ products in your home to experience them first hand

    Understand warranties, costs and impact on customers

    When Meeting with the Customer

    Discuss utility and government rebates to help customers when buying upgraded equipment

    Sell on homeowner benefits: explain product features and technology benefits the customer can understand

    Sell service agreements to keep systems running and provide product confidence

    Position your business as a comfort and IAQ specialist rather than just a low-price bidder

    Add new financing options that will make it easier for consumers to afford new systems (positive cash flow payments) ?Offer ductwork sealing and improvements to ensure proper functioning of new equipment

    Know the benefits of when to replace and when to repair a system for a customer